COATINGS RESEARCH GROUP, INC.
2340 Hamilton Avenue, Cleveland, Ohio 44114 U.S.A.
216-781-9122
* * *
FAX 216-781-9239
DATE: March 10,1993
|
TO:
|
Bill Setser
|
|
FROM:
|
Phil Slifko
|
|
SUBJECT:
|
Perm Rating of Indurall Sample Protecto 401
|
Procedure A of ASTM 96-66, described in Project 10-002 p 14-30 (February
1979), was used to determine the permeance of the submitted paint sample.
Over a period of thirty days in our humidity cabinet, relative humidity (outside
the cup) and temperature averaged 48.6% and 78.0°F (25.6°C), respectively.
Glidden's Insul-aid was used as the control in this test.
The permeance of the Protecto 401 (Q8-2401 [component A] blended with D8-
2401 [component B]) along with the control are shown in the following Table:
TABLE: Perm Rating of Test Coatings
Coating
Protecto 401
Glidden Insul-aid
|
Dry film
thickness
(mils)
53.00
2.36
|
Perms
0.00
0.63
|
|
*All samples were run in duplicate and averaged for permeance.
|
| |
Sincerely,

Phil Slifko
|
|
|