| Protecto 401 vs. Polyamide Coal Tar Epoxy
|
|
|
TEST
|
PROTECTO 401
|
POLYAMIDE COAL TAR EPOXY
|
|
PERMEABILITY
Procedure "A"
of ASTM E-96-66
42 Day Test Duration
|
0.00 perms
|
.22 perms
|
Note: The lower the permeability rating the less water borne chemicals can penetrate the lining.
|
IMMERSION
in 20% sulfuric acid
|
No blisters or de-
lamination of lining
after 24 months.
|
Blisters over all
of the tested area of
lining after 3 months.
Test terminated.
|
Note: (Rated using standards according to ASTM D714-87 Evaluating the degree of
blistering).
|
SALT SPRAY
5% solution
ASTM B 117-85
Scribed
|
24 months
No undercutting at
scribe. No damage
to panel.
|
After 4.7 months no
undercutting at scribe. No
damage to panel
|
Note: All materials were tested with an average film thickness of 40 mils.
|
|
|
|